Galindo-Moreno P, Leon-Cano A, Ortega-Oller I, Monje A, Ovalle F, Catena A. Marginal bone loss as success criterion in implant dentistry: beyond 2 mm. Clin Oral Implants Res. 2015;26(4):e28–34.
Galindo-Moreno P, Catena A, Pérez-Sayáns M, Fernández-Barbero JE, O’Valle F, Padial-Molina M. Early marginal bone loss around dental implants to define success in implant dentistry: a retrospective study. Clin Implant Dent Relat Res. 2022;24(5):630–42. https://doi.org/10.1111/cid.13122.
Article PubMed PubMed Central Google Scholar
Monje A, Roccuzzo A, Buser D, Wang HL. Influence of buccal bone wall thickness on the peri-implant hard and soft tissue dimensional changes: a systematic review. Clin Oral Implants Res. 2023;34(3):157–76. https://doi.org/10.1111/clr.14029.
Chen ST, Buser D, Sculean A, Belser UC. Complications and treatment errors in implant positioning in the aesthetic zone: diagnosis and possible solutions. Periodontol. 2000;2023(92):220–34. https://doi.org/10.1111/prd.12474.
Vervaeke S, Matthys C, Nassar R, Christiaens V, Cosyn J, De Bruyn H. Adapting the vertical position of implants with a conical connection in relation to soft tissue thickness prevents early implant surface exposure: a 2-year prospective intra-subject comparison. J Clin Periodontol. 2018;45(5):605–12.
Tarnow DP, Cho SC, Wallace SS. The effect of inter-implant distance on the height of inter-implant bone crest. J Periodontol. 2000;71(4):546–9. https://doi.org/10.1902/jop.2000.71.4.546.
Article CAS PubMed Google Scholar
Tarnow D, Elian N, Fletcher P, Froum S, Magner A, Cho SC, Salama M, Salama H, Garber DA. Vertical distance from the crest of bone to the height of the interproximal papilla between adjacent implants. J Periodontol. 2003;74(12):1785–8. https://doi.org/10.1902/jop.2003.74.12.1785.
Buser D, Martin W, Belser UC. Optimizing esthetics for implant restorations in the anterior maxilla: anatomic and surgical considerations. Int J Oral Maxillofac Implants. 2004;19(Suppl):43–61.
Cardaropoli G, Wennström JL, Lekholm U. Peri-implant bone alterations in relation to inter-unit distances. A 3-year retrospective study. Clin Oral Implants Res. 2003;14(4):430–6. https://doi.org/10.1034/j.1600-0501.2003.00895.x.
Scarano A, Assenza B, Piattelli M, Thams U, San Roman F, Favero GA, Piattelli A. Interimplant distance and crestal bone resorption: a histologic study in the canine mandible. Clin Implant Dent Relat Res. 2004;6(3):150–6. https://doi.org/10.1111/j.1708-8208.2004.tb00222.x.
Gastaldo JF, Cury PR, Sendyk WR. Effect of the vertical and horizontal distances between adjacent implants and between a tooth and an implant on the incidence of interproximal papilla. J Periodontol. 2004;75(9):1242–6. https://doi.org/10.1902/jop.2004.75.9.1242.
Kupershmidt I, Levin L, Schwartz-Arad D. Inter-implant bone height changes in anterior maxillary immediate and non-immediate adjacent dental implants. J Periodontol. 2007;78(6):991–6. https://doi.org/10.1902/jop.2007.060443.
Chang M, Wennström JL. Peri-implant soft tissue and bone crest alterations at fixed dental prostheses: a 3-year prospective study. Clin Oral Implants Res. 2010;21(5):527–34. https://doi.org/10.1111/j.1600-0501.2009.01874.x.
Schnitman PA, Hayashi C. Papilla formation in response to computer-assisted implant surgery and immediate restoration. J Oral Implantol. 2015;41(4):459–66. https://doi.org/10.1563/aaid-joi-D-14-00314.
Traini T, Novaes AB, Piattelli A, Papalexiou V, Muglia VA. The relationship between interimplant distances and vascularization of the interimplant bone. Clin Oral Implants Res. 2010;21(8):822–9. https://doi.org/10.1111/j.1600-0501.2010.01926.x.
Degidi M, Novaes AB Jr, Nardi D, Piattelli A. Outcome analysis of immediately placed, immediately restored implants in the esthetic area: the clinical relevance of different interimplant distances. J Periodontol. 2008;79(6):1056–61. https://doi.org/10.1902/jop.2008.070534.
Kourkouta S, Dedi KD, Paquette DW, Mol A. Interproximal tissue dimensions in relation to adjacent implants in the anterior maxilla: clinical observations and patient aesthetic evaluation. Clin Oral Implants Res. 2009;20(12):1375–85. https://doi.org/10.1111/j.1600-0501.2009.01761.x.
Novaes AB Jr, de Oliveira RR, Muglia VA, Papalexiou V, Taba M. The effects of interimplant distances on papilla formation and crestal resorption in implants with a morse cone connection and a platform switch: a histomorphometric study in dogs. J Periodontol. 2006;77(11):1839–49. https://doi.org/10.1902/jop.2006.060162.
Novaes AB Jr, Barros RR, Muglia VA, Borges GJ. Influence of interimplant distances and placement depth on papilla formation and crestal resorption: a clinical and radiographic study in dogs. J Oral Implantol. 2009;35(1):18–27. https://doi.org/10.1563/1548-1336-35.1.18.
de Oliveira RR, Novaes AB Jr, Papalexiou V, Muglia VA, Taba M Jr. Influence of interimplant distance on papilla formation and bone resorption: a clinical-radiographic study in dogs. J Oral Implantol. 2006;32(5):218–27. https://doi.org/10.1563/793.1.
de Oliveira RR, Novaes AB Jr, Taba M Jr, Papalexiou V, Muglia VA. Bone remodeling adjacent to Morse cone-connection implants with platform switch: a fluorescence study in the dog mandible. Int J Oral Maxillofac Implants. 2009;24(2):257–66.
Barros RR, Novaes AB Jr, Muglia VA, Iezzi G, Piattelli A. Influence of interimplant distances and placement depth on peri-implant bone remodeling of adjacent and immediately loaded Morse cone connection implants: a histomorphometric study in dogs. Clin Oral Implants Res. 2010;21(4):371–8. https://doi.org/10.1111/j.1600-0501.2009.01860.x.
Elian N, Bloom M, Dard M, Cho SC, Trushkowsky RD, Tarnow D. Radiological and micro-computed tomography analysis of the bone at dental implants inserted 2, 3 and 4 mm apart in a minipig model with platform switching incorporated. Clin Oral Implants Res. 2014;25(2):e22–9. https://doi.org/10.1111/clr.12037.
Elian N, Bloom M, Trushkowsky RD, Dard MM, Tarnow D. Effect of 3- and 4-mm interimplant distances on the height of interimplant bone crest: a histomorphometric evaluation measured on bone level dental implants in minipig. Implant Dent. 2014;23(5):522–8. https://doi.org/10.1097/ID.0000000000000153.
Nevins M, Nevins M, Gobbato L, Lee HJ, Wang CW, Kim DM. Maintaining interimplant crestal bone height via a combined platform-switched, Laser-Lok implant/abutment system: a proof-of-principle canine study. Int J Periodontics Restorative Dent. 2013;33(3):261–7. https://doi.org/10.11607/prd.1773.
Koutouzis T, Neiva R, Lipton D, Lundgren T. The effect of interimplant distance on peri-implant bone and soft tissue dimensional changes: a nonrandomized, prospective, 2-year follow-up study. Int J Oral Maxillofac Implants. 2015;30(4):900–8. https://doi.org/10.11607/jomi.4040.
Nevins M, Leziy S, Kerr E, Janke U, Rasperini G, Hanratty J, Pasquinelli K, Testori T, Shapoff CA, Kim DM. A prospective clinical and radiographic assessment of platform-switched laser-microchannel implants placed in limited interimplant spaces. Int J Periodontics Restorative Dent. 2017;37(1):33–8. https://doi.org/10.11607/prd.3109.
Hatley CL, Cameron SM, Cuenin MF, Parker MH, Thompson SH, Harvey SB. The effect of dental implant spacing on peri-implant bone using the rabbit (Oryctolagus cuniculus) tibia model. J Prosthodont. 2001;10(3):154–9. https://doi.org/10.1111/j.1532-849x.2001.00154.x.
Article CAS PubMed Google Scholar
Hermann JS, Buser D, Schenk RK, Cochran DL. Crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged and submerged implants in the canine mandible. J Periodontol. 2000;71(9):1412–24. https://doi.org/10.1902/jop.2000.71.9.1412.
Article CAS PubMed Google Scholar
Broggini N, McManus LM, Hermann JS, Medina RU, Oates TW, Schenk RK, Buser D, Mellonig JT, Cochran DL. Persistent acute inflammation at the implant-abutment interface. J Dent Res. 2003;82(3):232–7. https://doi.org/10.1177/154405910308200316.
Comments (0)