Dual-ended readout TOF-DOI PET detectors based on 3.2 mm and 1.6 mm pitch LYSO arrays

Cherry SR, Dahlbom M. PET: physics, instrumentation, and scanners. In: Cherry SR, Dahlbom M, Phelps ME, editors. PET Phys Instrum Scanners. New York: Springer; 2006. p. 1–117.

Google Scholar 

Cherry SR. The 2006 Henry N. Wagner Lecture: of mice and men (and positrons)—advances in PET imaging technology. J Nucl Med. 2006;47:1735–45.

Karakatsanis NA, Fokou E, Tsoumpas C. Dosage optimization in positron emission tomography: state-of-the-art methods and future prospects. Am J Nucl Med Mol Imaging. 2015;5:527–47.

CAS  PubMed  PubMed Central  Google Scholar 

Cherry SR, Jones T, Karp JS, Qi J, Moses WW, Badawi RD. Total-body PET: maximizing sensitivity to create new opportunities for clinical research and patient care. J Nucl Med. 2018;59:3–12.

Article  CAS  PubMed  PubMed Central  Google Scholar 

Yamagishi S, Miwa K, Kamitaki S, Anraku K, Sato S, Yamao T, et al. Performance characteristics of a new-generation digital bismuth germanium oxide PET/CT system, omni legend 32, according to NEMA NU 2–2018 standards. J Nucl Med. 2023;64:1990–7.

Article  CAS  PubMed  Google Scholar 

Prenosil GA, Sari H, Fürstner M, Afshar-Oromieh A, Shi K, Rominger A, et al. Performance characteristics of the biograph vision quadra PET/CT system with a long axial field of view using the NEMA NU 2–2018 standard. J Nucl Med. 2022;63:476–84.

Article  CAS  PubMed  Google Scholar 

Spencer BA, Berg E, Schmall JP, Omidvari N, Leung EK, Abdelhafez YG, et al. Performance evaluation of the uEXPLORER total-body PET/CT scanner based on NEMA NU 2-2018 with additional tests to characterize PET scanners with a long axial field of view. J Nucl Med. 2021;62:861–70.

Article  PubMed  PubMed Central  Google Scholar 

Vandenberghe S, Moskal P, Karp JS. State of the art in total body PET. EJNMMI Phys. 2020;7:35.

Article  PubMed  PubMed Central  Google Scholar 

Li G, Ma W, Li X, Yang W, Quan Z, Ma T, et al. Performance evaluation of the uMI panorama PET/CT system in accordance with the national electrical manufacturers association NU 2–2018 standard. J Nucl Med. 2024;65:652–8.

Article  Google Scholar 

Lecoq P, Morel C, Prior JO, Visvikis D, Gundacker S, Auffray E, et al. Roadmap toward the 10 ps time-of-flight PET challenge. Phys Med Biol. 2020;65:21RM01.

Karp JS, Surti S, Daube-Witherspoon ME, Muehllehner G. Benefit of time-of-flight in PET: experimental and clinical results. J Nucl Med Off Publ Soc Nucl Med. 2008;49:462–70.

Google Scholar 

Vandenberghe S, Mikhaylova E, D’Hoe E, Mollet P, Karp JS. Recent developments in time-of-flight PET. EJNMMI Phys. 2016;3:3.

Article  CAS  PubMed  PubMed Central  Google Scholar 

Schaart DR. Physics and technology of time-of-flight PET detectors. Phys Med Biol. 2021;66:09TR01.

Conti M, Bendriem B. The new opportunities for high time resolution clinical TOF PET. Clin Transl Imaging. 2019;7:139–47.

Article  Google Scholar 

Conti M. Focus on time-of-flight PET: the benefits of improved time resolution. Eur J Nucl Med Mol Imaging. 2011;38:1147–57.

Article  PubMed  Google Scholar 

Surti S. Update on time-of-flight PET imaging. J Nucl Med Off Publ Soc Nucl Med. 2015;56:98–105.

Google Scholar 

Berg E, Cherry SR. Innovations in instrumentation for positron emission tomography. Semin Nucl Med. 2018;48:311–31.

Article  PubMed  PubMed Central  Google Scholar 

Schaart DR, Schramm G, Nuyts J, Surti S. Time of flight in perspective: instrumental and computational aspects of time resolution in positron emission tomography. IEEE Trans Radiat Plasma Med Sci. 2021;5:598–618.

Article  PubMed  PubMed Central  Google Scholar 

Moses WW. Fundamental limits of spatial resolution in PET. Nucl Instrum Methods Phys Res Sect Accel Spectrometers Detect Assoc Equip. 2011;648(Supplement 1):S236–40.

Article  CAS  Google Scholar 

Akamatsu G, Tashima H, Iwao Y, Wakizaka H, Maeda T, Mohammadi A, et al. Performance evaluation of a whole-body prototype PET scanner with four-layer DOI detectors. Phys Med Biol. 2019;64: 095014.

Article  CAS  PubMed  Google Scholar 

Kuang Z, Sang Z, Ren N, Wang X, Zeng T, Wu S, et al. Development and performance of SIAT bPET: a high-resolution and high-sensitivity MR-compatible brain PET scanner using dual-ended readout detectors. Eur J Nucl Med Mol Imaging. 2024;51:346–57.

Article  CAS  PubMed  Google Scholar 

Zeng X, Wang Z, Tan W, Petersen E, Cao X, LaBella A, et al. A conformal TOF-Prism-PET prototype scanner for high-resolution quantitative neuroimaging. Med Phys. 2023.

Li H, Badawi RD, Cherry SR, Fontaine K, He L, Henry S, et al. Performance characteristics of the NeuroEXPLORER, a next-generation human brain PET/CT imager. J Nucl Med. 2024.

Du J, Bai X, Gola A, Acerbi F, Ferri A, Piemonte C, et al. Performance of a high-resolution depth-encoding PET detector module using linearly-graded SiPM arrays. Phys Med Biol. 2018;63: 035035.

Article  PubMed  PubMed Central  Google Scholar 

Du J, Ariño-Estrada G, Bai X, Cherry SR. Performance comparison of dual-ended readout depth-encoding PET detectors based on BGO and LYSO crystals. Phys Med Biol. 2020;65: 235030.

Article  CAS  Google Scholar 

Yang Q, Kuang Z, Sang Z, Yang Y, Du J. Performance comparison of two signal multiplexing readouts for SiPM-based pet detector. Phys Med Biol. 2019;64:23NT02.

Watanabe M, Saito A, Isobe T, Ote K, Yamada R, Moriya T, et al. Performance evaluation of a high-resolution brain PET scanner using four-layer MPPC DOI detectors. Phys Med Biol. 2017;62:7148–66.

Article  CAS  PubMed  Google Scholar 

Pourashraf S, Gonzalez-Montoro A, Won JY, Lee MS, Cates JW, Zhao Z, et al. Scalable electronic readout design for a 100 ps coincidence time resolution TOF-PET system. Phys Med Biol. 2021;66: 085005.

Article  CAS  Google Scholar 

Ito M, Lee JS, Kwon SI, Lee GS, Hong B, Lee KS, et al. A four-layer DOI detector with a relative offset for use in an animal PET system. IEEE Trans Nucl Sci. 2010;57:976–81.

Article  Google Scholar 

Kang HG, Nishikido F, Yamaya T. A staggered 3-layer DOI PET detector using BaSO4 reflector for enhanced crystal identification and inter-crystal scattering event discrimination capability. Biomed Phys Eng Express. 2021;7: 035018.

Article  Google Scholar 

Carra P, Bisogni MG, Ciarrocchi E, Morrocchi M, Sportelli G, Rosso V, et al. A neural network-based algorithm for simultaneous event positioning and timestamping in monolithic scintillators. Phys Med Ampmathsemicolon Biol. 2022;67: 135001.

Article  Google Scholar 

Zhang X, Wang X, Ren N, Hu B, Ding B, Kuang Z, et al. Performance of long rectangular semi-monolithic scintillator PET detectors. Med Phys. 2019;46:1608–19.

Article  PubMed  Google Scholar 

Tsuda T, Murayama H, Kitamura K, Yamaya T, Yoshida E, Omura T, et al. A four-layer depth of interaction detector block for small animal PET. IEEE Trans Nucl Sci. 2004;51:2537–42.

Article  Google Scholar 

Du J. Performance of dual-ended readout PET detectors based on BGO arrays and BaSO₄ reflector. IEEE Trans Radiat Plasma Med Sci. 2021;6:522–8.

Article  PubMed  PubMed Central  Google Scholar 

Derenzo SE, Choong W-S, Moses WW. Fundamental limits of scintillation detector timing precision. Phys Med Biol. 2014;59:3261.

Article  PubMed  PubMed Central  Google Scholar 

Kang HG, Yamaya T, Han YB, Song SH, Ko GB, Lee JS, et al. Crystal surface and reflector optimization for the SiPM-based dual-ended readout TOF-PET detector. Biomed Phys Eng Express. 2020.

Liu Z, Niu M, Kuang Z, Ren N, Wu S, Cong L, et al. High resolution detectors for whole-body PET scanners by using dual-ended readout. EJNMMI Phys. 2022;9:29.

Article  PubMed  PubMed Central  Google Scholar 

Du J, Schmall JP, Di K, Yang Y, Judenhofer M, Bec J, et al. Design and optimization of a high-resolution PET detector module for small-animal PET based on a 12 × 12 silicon photomultiplier array. Biomed Phys Eng Express. 2015;1: 045003.

Article  Google Scholar 

Francesco AD, Bugalho R, Oliveira L, Pacher L, Rivetti A, Rolo M, et al. TOFPET2: a high-performance ASIC for time and amplitude measurements of SiPM signals in time-of-flight applications. J Instrum. 2016;11:C03042.

Article  Google Scholar 

Bugalho R, Di Francesco A, Ferramacho L, Leong C, Niknejad T, Oliveira L, et al. Experimental results with TOFPET2 ASIC for time-of-flight applications. Nucl Instrum Methods Phys Res Sect Accel Spectrometers Detect Assoc Equip. 2018;912:195–8.

Article  CAS  Google Scholar 

Pani R, Vittorini F, Cinti MN, Bennati P, Pellegrini R, Ridolfi S, et al. Revisited position arithmetics for LaBr 3: Ce continuous crystals. Nucl Phys B Proc Suppl. 2009;197:383–6.

Article  CAS  Google Scholar 

Comments (0)

No login
gif