Friction (FR) is defined as the resistive force between surfaces that opposes motion.[1] When two objects come in contact, the force works in the opposite direction of the moving body or surface, slowing or resisting their relative motion.[2] Friction is contributed by multifactorial characteristics that include both biological and mechanical variables. Sliding mechanics used for closing extraction space result in relative movement to occurs between the archwire and bracket interface resulting in frictional resistance.[3] Frictional resistance modifies the moment-to-force ratio of teeth and rotational center, hence influencing the orthodontic tooth movement rate and raising the risk of anchoring loss.[4]
Surface roughness is the trait of the material, shelf life, and manufacturing process. A smooth surface results in a vast area of adhesion that increases friction during sliding motion and a rough surface creates significant friction due to contact and interlocking between the peaks of the surface and the valley.[5] Various techniques are available to overcome friction during orthodontic tooth movement these include the use of extraoral force, temporary anchorage devices, or archwires of different materials, sizes, and shapes. Nanoparticles were used as a method to reduce the friction between metallic surfaces in the form of solid lubricant.[6]
One way to modify the material surface is through coating. Different coating techniques and materials have been used to enhance the surface properties of archwires. Nevertheless, some problems with coatings have been observed. Investigations are continuing to find appropriate materials and techniques with the objective of improving the properties of metallic biomaterials. Elhelbawy and Ellaithy showed that the coating of stainless steel (SS) orthodontic brackets and wires by nanoparticles of Chitosan or Zinc oxide (ZnO) during frictional test reduced the frictional force significantly resulting in better anchorage control, reduced treatment time, and risk of root resorption.[7] It was demonstrated by Ghasemi et al.[8] that titanium dioxide (TiO2)-coated brackets substantially reduced surface roughness which, in turn, reduced the colonization of Streptococcus mutans. Arici et al. suggests that the coefficients of friction of metal bracket–archwire combinations used in orthodontic treatment can be decreased by coating with Al2O3 and TiN thin film.[9] Orthodontic archwires are coated with nanoparticles to influence their surface features and, consequently, their properties. Such a coating can be done using TiO2. Radiofrequency (RF) magnetron sputtering is an effective technique on account of its inherent versatility, low-temperature deposition, and uniform surface coverage. The main advantage of this method is the ability to apply a thin, inorganic, and nanoparticle coating with an adjustable shape and size by tuning preparation parameters.[10] Therefore, the present study was designed to assess and compare the frictional resistance, and surface roughness of TiO2 nanoparticles coated SS straight wire with conventional SS wire, and the film integrity of the coating after undergoing a frictional test done with RF magnetron sputtering technique. The current study tested the null hypothesis pointing no difference between frictional resistance and surface roughness generated by TiO2 nanocoated stainless steel wire and conventional stainless steel wires.
MATERIAL AND METHODSThe study was conducted in Sree Chitra Tirunal Institute of Medical Science and Technology, Biomedical Technology wing, Trivandrum, Kerala.
Eighteen rectangular straight SS archwires of 0.019 × 0.025 inches were divided into two groups. The experimental group consisted of nine wires coated with TiO2 by RF magnetron sputtering method compared with nine uncoated control groups [Figure 1].
Export to PPT
Samples size was calculated based on n = (Zα/2 + Zβ)2 × 2 × σ2/d2, Zα/2 = 1.96% at 95% confidence interval, Zβ = 2.33 at 99% power of the study, σ2 = 0.09, d = 0.6, n = 9.2 = 9 nos per group, with the final sample size of 9 + 9 = 18 nos to check the difference in frictional value and surface roughness.
Coating of the wireRF magnetron sputtering was used to deposit a film of TiO2 nanocoating of thickness 800Ǻ on the experimental SS straight wire. The RF Sputtering system contains an SS deposition vacuum chamber. Substrates are placed in a vacuum chamber and are pumped down to a prescribed process pressure. Sputtering starts when a negative charge is applied to the target material causing a plasma or glow discharge. The negatively based target plate is quickly drawn to the positively charged gas ions produced in the plasma area. This collision creates a momentum transfer and ejects atomic-size particles from the target. As a result, these particles are applied as a thin layer on the surface of the substrate. After cleaning the experimental samples with acetone, the sample was placed in the base plate holder and secured with a ketone tape. Each sample was coated on one side and after coating on one side, the samples were flipped and kept for the same coating on the opposite side.
Frictional testA single equivalent force acting at the root’s center of resistance was used to approximate the forces acting on the tooth root’s surface. The force acting on the archwire is counteracted by the couple created by the two-point contact.[11]
Eighteen specimens from both groups (length of 60 mm) were analyzed for the evaluation of frictional resistance at bracket and wire interface using Tidy’s protocol under dry conditions [Figure 2].[11] Four edgewise brackets (Victory Series, 3M Unitek) having a slot dimension of 0.022 × 0.028 inches were positioned at 8 mm intervals (inter bracket distance) on an acrylic plate for friction testing, with a 16 mm gap (retraction space) in the middle to allow the canine bracket to slide to replicate canine retraction.
Export to PPT
In the present study, rather than the bracket itself, a power arm was used to exert the force necessary for retraction. Power arm mechanics are used in the clinical setting, and they are replicated here. The experimental configuration of tidy serves as the foundation. However, due to the effects of binding and notching, the frictional resistance may vary when the force is applied directly to the bracket. Therefore, the findings can be applied in a clinical setting where retraction is accomplished using a power arm or an archwire hook.[12]
Initially, the ligature on the movable bracket was tightened completely and then loosened to allow free sliding. The movable bracket was equipped with a 12 mm power arm, from which weights of 0.5 N and 1 N were hung to simulate the single equivalent force acting at the tooth root’s center of resistance. The power arm’s length was selected to represent the distance from the slot to the center of resistance of a typical canine tooth. Metallic ligatures measuring 0.010 inches were used to secure the wires.
All tests were conducted under dry conditions, texture analyzer (Model and manufacturer: TA.XT Plus [Stable Micro Systems, UK]) was used for the study with a movable bracket suspended from the load cell of the testing machine, while the base plate (Perspex sheet) was mounted on the crosshead below.
Tooth movement typically progresses at a rate of around 1 mm per month, corresponding to an average speed of approximately 2.3 × 10–5 mm per minute. For the experiment, a speed of 5 mm/min was selected, as higher speeds did not accurately reflect real clinical conditions. A study examining the effect of varying crosshead speeds (ranging from 0.5 to 50 mm/min) on frictional resistance using an Instron universal testing machine found no significant differences in the results.[13]
The load cell reading represents the clinical force of retraction that would be applied to the canine, part of which would be critical friction while the rest would be the translation force on the tooth. The difference between the load cell reading and the load on the power arm represents frictional resistance. The coefficient of friction at the wire-bracket interface was calculated using the appropriate formula, P = 2Fhm/W, where (P: Frictional resistance, F: Equivalent force acting at a distance, W: Bracket slot width, h: 12 mm, and m: Coefficient of friction).
Scanning electron microscopy (SEM)SEM attached with an energy-dispersive X-ray analysis system with OXFORD Link Ultracool Detector, having a resolution of 133eV/Mn was used to check the surface of the coated wire and the uniformity of the coating. Samples were mounted using a suitable grip and analysis was performed at different magnifications ×100, ×500, and for both coated and uncoated wire [Figure 3a and b].
Export to PPT
Surface roughness testThe TiO2 coated and uncoated wires were subjected to a surface roughness test using optical profiling (VEECO TECHNOLOGIES VS1000). The samples were mounted on the wedge using a suitable grip and a test was conducted. After the samples were mounted, optical profiling analysis was performed using the Vecco Surface profiler. Crosshead is selected with speed for scan length 1 um × 1 um. To determine the average roughness using a surface profilometer, 1.6 mm × 1.6 mm samples were obtained from the area where canine bracket sliding occurred. Samples were set with the American Society for Testing Materials standard: ISO4287. Surface roughness data reported in Arithmetic Roughness Ra Root Mean Square Rq in um scale.
TiO2 film integritySEM before and after the frictional test at ×100, ×300, and ×1000 was done to the test material obtained from the part of the wire that underwent canine retraction, to check the integrity of TiO2 nanocoating after the frictional test [Figure 4].
Export to PPT
RESULTSThe present study compared the frictional value of coated TiO2 and uncoated SS wires. The data were collected, coded, and fed in the Statistical Package for the Social Sciences (IBM version 23) for statistical analysis. The descriptive statistics included mean and standard deviation. The inferential statistics included an Independent “t”-test for comparison between the two groups. The level of significance was set at 0.05 at a 95% confidence interval.
Frictional resistanceIn the present study, evaluation of frictional resistance at bracket and wire interface was conducted under dry conditions using TiO2 nanocoated wire at 0.5 N and 1 N weight showed frictional resistance and coefficient of friction of 2.14 ± 0.35 N and 0.18 ± 0.05 with 0.5N [Table 1] and frictional resistance of 2.79 ± 0.30N and coefficient of friction of 0.16 ± 0.09 with 1 N [Table 2]. The uncoated SS wire showed a frictional resistance of 1.15 ± 0.22 N and coefficient of friction of 0.16 ± 0.01 with 0.5 N of weight [Table 3] and a frictional resistance of 1.63 ± 0.84N and a coefficient of friction of 0.14 ± 0.03 with 1 N of weight [Table 4]. The results indicated higher values of frictional resistance due to the proportional relationship between friction and applied load, while the coefficient of friction remained relatively constant for given material pairs. This suggests that as the load increases, the frictional resistance also increases, but the inherent material properties (coefficient of friction) do not change significantly. Therefore, the frictional resistance can be high even if the coefficient of friction is low, depending on the applied load.
Table 1: Titanium dioxide coated wire frictional resistance and coefficient of friction with 0.5 N weight.
Mean Standard deviation t-value Sig. Frictional resistance 0.5 N 2.14 0.35 −4.16 0.001 (HS) Coefficient of friction 0.5 N 0.18 0.005 5.84 0.000 (HS)Table 2: Titanium dioxide coated wire frictional resistance and coefficient of friction with 1 N weight.
Mean Standard deviation t-value Sig. Frictional resistance 1 N 2.79 0.30 −4.16 0.001 (HS) Coefficient of friction 1 N 0.16 0.008 5.84 0.000 (HS)Table 3: Uncoated stainless steel wire frictional resistance and coefficient of friction with 0.5 N weight.
Mean Standard deviation t-value Sig. Frictional resistance 0.5 N 1.15 0.22 −1.64 0.120 (NS) Coefficient of friction 0.5 N 0.16 0.01 1.34 0.197 (NS)Table 4: Uncoated stainless steel wire frictional resistance and coefficient of friction with 1 N weight.
Mean Standard deviation t-value Sig. Frictional resistance 1 N 1.63 0.84 −1.64 0.120 (NS) Coefficient of friction 1 N 0.14 0.03 1.34 0.197 (NS)Frictional resistance generally increased with greater applied normal force for both dry and wet conditions, but the mean coefficients of friction are higher in wet conditions due to increased atomic attraction among ionic species. Stannard et al. stated that the average coefficient of variation is 12.56% for dry conditions and 14.88% for wet conditions, indicating more dispersion in the wet conditions.[14]
On comparison of the mean frictional resistance at 0.5 N, a statistically significant difference between TiO2 coated SS wire and uncoated SS wire (P < 0.05, P = 0.000) was seen. With 1 N comparing the mean frictional resistance showed a highly significant difference between TiO2 coated SS wire and uncoated SS wire (P < 0.05, P = 0.001) [Table 5 and Graph 1].
Table 5: Comparison of mean frictional resistance at 0.5 N and 1 N between TiO2 coated SS wires and uncoated wires.
Mean Standard deviation t-value Sig. 0.5 N TiO2 SS coated wires 2.146778 0.3535738 7/046 0.000 (HS) Uncoated SS coated wires 1.158667 0.2280433 1 N TiO2 SS coated wires 2.796000 0.3069446 3.847 0.001 (HS) Uncoated SS coated wires 1.639000 0.8485027
Export to PPT
Surface roughness testThe physical appearance of the surface shows a uniform dense titanium coating layer under SEM and relatively smooth morphology for coated samples when compared to uncoated samples, indicating no abrasion/pitting, which was in accordance with the findings of Anuradha et al. [15]
When a bandpass of the specimen is selected using an optical profilometer, a filtered surface is obtained showing the surface roughness. This texture diffuses light from different angles. Proper spatial filtering reveals through mean roughness differ between mirrors. An increase in amplitude roughness also increases the diffusion of light and this diffusion directly scopes with efficiency of reflectivity. These show mean roughness parameters to quantify the appearance and reflectivity efficiency of the mirrors [Figures 5 and 6].[16]
Export to PPT
Export to PPT
The mean surface roughness of TiO2 nanocoated wires and uncoated SS wire was 0.037 ± 0.09 Ra and 0.28 ± 0.06 Ra, respectively. There was a statistically significant difference noted when comparing between two types of wires (P < 0.05, P = 0.000). The surface roughness of TiO2 nanocoated SS wire is better than uncoated SS wire [Table 6 and Graph 2 ].
Table 6: Comparison of surface roughness between TiO2 SS coated wires and uncoated SS wires.
Mean Standard deviation t-value Sig. TiO2 nano coated wires 0.037 0.008 -11.315 0.000 (HS) Uncoated SS wires 0.281 0.06
Export to PPT
TiO2 film integrityFigure 3 shows a scanning electron micrograph of uncoated and TiO2 coated wire at ×100, ×500 magnification. The coated wires showed the presence of titanium peaks only, indicating the absence of any secondary phase formation during the sputtering process.
SEM before and after the frictional test at ×100, ×300, and ×1000 showed delamination, deterioration, and peeling off of the coating in the TiO2 nanocoated group [Figure 4].
DISCUSSIONThe frictional force between the bracket and the wire is a crucial aspect of clinical orthodontics. Reducing this frictional force can enhance the efficiency of tooth movement, thereby shortening the treatment duration.
Nevertheless, during the sliding process, friction between the bracket and wire interface is unavoidable, resulting in the application of greater forces to overcome the friction, which can result in anchorage loss.[17] Previous studies have shown a reduction in surface roughness and friction on the coating of archwires with a diamond-like carbon coating, ZnO, Zirconium oxide, Teflon, and inorganic fullerene-like tungsten nanoparticles.[16-28] Hence, the present study was conducted to evaluate the surface roughness and efficiency of TiO2 nanocoated SS wires for reduction of frictional resistance during sliding mechanics and the persistence of coating after the frictional test using RF magnetron sputtering technique.
Furthermore, most studies on nanoparticle-coated TiO2 have focused on bacterial adhesion using the photocatalytic activity of TiO2. In the present study, a surface roughness test was carried out using optical profiling (VEECO TECHNOLOGIES VS1000) for TiO2 coated SS wires and to compare with uncoated SS wires. Our study results showed increased surface roughness of 0.28 ± 0.06 uncoated SS wire when compared with TiO2 nanocoated SS wire 0.03 ± 0.08, which was in accordance with the study by Venkatesan et al. indicating that coated wires were smoother compared to uncoated wires.[28] A similar study done by Anuradha et al. reported that sputter coating with TiO2 particles on the archwires decreased the surface roughness.[15,28] A systemic review by Solanki et al. concluded that TiO2 coated brackets showed reduced surface roughness, minimal bacterial adhesion, and less cytotoxic activity.[26]
Ghasemi et al. utilized titanium oxide and silver oxide nanofilms of different thicknesses (60 and 100 um) and found that friction among silver oxide-coated brackets was lower than that of the titanium oxide and uncoated brackets; also, atomic force microscopy showed smoother surface in coated brackets.[8] The friction on brackets with titanium oxide coating increased at both 60 and 100 um thickness. The present results are incongruent with the above. On evaluation of the effect of RF magnetron sputtered TiO2 wires on frictional resistance, results showed an increase in frictional resistance and coefficient of friction in both 0.5 N and 1 N groups. The mean frictional resistance at 0.5N of TiO2 coated SS wire and uncoated SS wire was 2.15 ± 0.35 and 1.15 ± 0.22, respectively. The mean frictional resistance at 1 N of TiO2 coated SS wire and uncoated SS wire was 2.79 ± 0.30 and 1.64 ± 0.84, respectively. In addition, the SEM image after the frictional test showed peeling off of the coating. This finding was in accordance with Venkatesan et al. and Arici et al.[9,28] On the evaluation of frictional resistance and peeling of coating among titanium coated arch wires, Chaturvedi et al., showed reduced friction among SS wire coated with sol gel concentration of 1:2–1:6 for a duration of 48 h.[29] In contrast, Ghasemi et al. coated SS wire with titanium oxide using a physical vapor deposition technique which showed increased friction with both 60 um and 100 um thickness; similarly, Arici et al. used TiN to coat SS wire with RF/Direct current (DC) magnetron sputtering and found peeling off the coating after the frictional test.[8,9] In the present study, the increased frictional resistance between the wire and bracket interface can be contributed due to the peeling off of the coating, the residual coating material at the point of contact point between the surfaces could be the reason for the increased friction. This peeling can be contributed to thermal expansion differences between the base material and coating materials similar to the study done by Arici et al.[9] In a recent study, the surface of chromium-nickel (Cr-Ni) archwires was examined in relation to silicon dioxide and TiO2 nanoparticles. The results indicated that TiO2 did not significantly reduce friction and TiO2 coating promoted the most heterogeneous surface morphology of Cr-Ni orthodontic wire.[30] Previous studies show that the coating technique and conditions play an important role in determining the frictional characteristics of the end product.[29]
For the reduction of frictional resistance, the present study used the RF magnetron sputtering technique to coat TiO2 on SS wire, however following the frictional test, the coating peeled off resulting in an increase in frictional resistance. Study results revealed higher friction when compared to the sol gel technique, a study by Chaturvedi et al. indicating that the sol gel method is a better choice when compared with the RF sputtering method in coating TiO2.[29] In a systemic review by Zhang et al., the deformation and peeling of the surface morphology was one of the reasons for greater frictional force among TiO2 coated brackets.[31] Similarly, the application of TiO2 coatings on SS brackets using PVD did not reduce friction.[32]
Limitation of the studyFurther research is to be done by altering the size of nanoparticles and the thickness of the coating.
CONCLUSIONTiO2 nanocoated SS wires showed a reduction in surface roughness compared to uncoated SS wire under an optical profilometer. The frictional test among the groups showed increased frictional resistance with TiO2 nanocoated wire compared to uncoated SS wire done with the RF sputtering technique.