Lee, J.E.: Visual acuity test. In: Lee, J.S. (ed.) Primary Eye Examination: A Comprehensive Guide to Diagnosis, pp. 1–12. Springer, Singapore (2019)
Ma, S., Li, C., Sun, J., Yang, J., Wen, K., Chen, X., Zhao, F., Sun, X., Tian, F.: Comparative analysis of eighteen IOL power calculation formulas using a modified formula performance index across diverse biometric parameters. Am. J. Ophthalmol. 273, 221–230 (2025)
Liu, J., Lu, Y., Liu, J., Wei, C.: Meta-analysis of efficacy, safety, stability and predictability of small incision lenticule extraction (SMILE) for myopia. Lasers Med. Sci. 39, 57 (2024)
Chen, X., Wang, X., Xu, Y., Cheng, M., Han, T., Niu, L., Wang, X., Zhou, X.: Five-year outcomes of EVO implantable collamer lens implantation for the correction of high myopia and super high myopia. Eye Vis. (Lond). 8, 40 (2021)
Kamiya, K., Shimizu, K., Takahashi, M., Ando, W., Hayakawa, H., Shoji, N.: Eight-year outcomes of implantation of posterior chamber phakic intraocular lens with a central port for moderate to high ametropia. Front. Med. (Lausanne). 8, 799078 (2021)
Kaiser, P.K.: Prospective evaluation of visual acuity assessment: a comparison of snellen versus ETDRS charts in clinical practice (An AOS Thesis). An AOS thesis. Trans. Am. Ophthalmol. Soc. 107, 311–324 (2009)
International Organization for Standardization: Ophthalmic optics—Visual acuity testing—Standard and clinical optotypes and their presentation (ISO 8596:2017). ISO, Geneva (2017)
Japanese Standards Association: Visual acuity testing equipment (JIS T 7309:2002). Japanese Standards Association, Tokyo (2002)
Tamai, H., Toyonaga, Y., Nagasawa, Y., Hori, H., Tsumura, A., Sasaki, N., et al.: Usefulness of space saving chart type II. Japanese Orthoptic J. 29, 121–125 (2001)
Tsumura, A., Sasaki, N., Fukui, C., Iwashita, K., Yuge, K., Okami, T., et al.: Clinical experience with a space-saving visual acuity test chart (SSC-330, type II). Folia Ophthalmol. Jpn. 53, 40–44 (2002)
Kucika, A., Rumjanceva, I., Patrova, T., Svede, A.: The effect of viewing distance on subjective refraction assessment. Proc. Est. Acad. Sci. 70, 317–325 (2021)
Mathebula, S.D., Rubin, A.: Interexaminer reproducibility for subjective refractions for an ametropic participant. BMJ Open. Ophthalmol. 7, e000954 (2022)
Sheppard, A.L., Davies, L.N.: Clinical evaluation of the Grand Seiko Auto Ref/Keratometer WAM-5500. Ophthalmic Physiol. Opt. 30, 143–151 (2010)
Chinn, R.N., Raghuram, A., Curtiss, M.K., Gehring, A.M., De Paula, A.J., Roberts, T.L.: Repeatability of the accommodative response measured by the grand Seiko autorefractor in children with and without amblyopia and adults. Am. J. Ophthalmol. 236, 221–231 (2022)
Pujol, J., Ondategui-Parra, J.C., Badiella, L., Otero, C., Vilaseca, M., Aldaba, M.: Spherical subjective refraction with a novel 3D virtual reality based system. J. Optom. 10, 43–51 (2016)
Bennett, A.G.: An historical review of optometric principles and techniques. Ophthalmic Physiol. Opt. 6, 3–21 (1986)
Yi, Z., Jie, G., Kai, C., Jing, S., Wei, Z., Yun, D.: Theoretical derivation and clinical validation of the resolution limit of human eye to spherical lens change: A self-controlled study. Int. Ophthalmol. 43, 1387–1394 (2023)
Li, J., Zhen, J., Xie, K., Yao, K., Liu, Z., Li, X.: The effect of 0.05D interval precise refraction on small-incision lenticule extraction surgery: A retrospective study with short-term follow-up. Clin. Optom. (Auckl). 16, 341–348 (2024)
Xu, J., Jiang, J., Chen, S., Li, Z., Xiao, Y.: Enhanced visual quality with 0.05D interval subjective refraction: a self-controlled study. Invest. Ophthalmol. Vis. Sci. 66, 2114 (2025)
Duan, Z., Tang, N., Wang, Y.: Comparison of dynamic visual acuity in spectacles prescribed to 0.05D versus 0.25D steps: a self-control, randomized study. Photonics. 12, 692 (2025)
Comments (0)