The development and use of isotope dilution mass spectrometry methods for the quantification of target proteins in certified reference materials

Schoenheimer R, Rittenberg D. Deuterium as an Indicator in the study of intermediary metabolism. Science. 1935;82(2120):156–7. https://doi.org/10.1126/science.82.2120.156.

Article  PubMed  CAS  Google Scholar 

Hevesy G, Paneth FA. A manual of radioactivity. Second edition. Oxford University Press, H Milford; 1926.

Heumann KG. Isotope dilution mass spectrometry (IDMS) of the elements. Mass Spectrom Rev. 1992;11(1):41–67. https://doi.org/10.1002/mas.1280110104.

Article  CAS  Google Scholar 

Zeisler R, Murphy KE, Becker DA, Davis WC, Kelly WR, Long SE. Standard Reference Materials® (SRMs) for measurement of inorganic environmental contaminants. Anal Bioanal Chem. 2006;386(4):1137–51. https://doi.org/10.1007/s00216-006-0785-7.

Vogl J, Pritzkow W. Isotope dilution mass spectrometry — a primary method of measurement and its role for RM certification. Mapan. 2010;25(3):135–64. https://doi.org/10.1007/s12647-010-0017-7.

Article  Google Scholar 

de Leenheer AP, Thienpont LM. Applications of isotope dilution-mass spectrometry in clinical chemistry, pharmacokinetics, and toxicology. Mass Spectrom Rev. 1992;11(4):249–307. https://doi.org/10.1002/mas.1280110402.

Article  Google Scholar 

White V E, Welch MJ, Sun T, Sniegoski LT, Schafter R, Hertz HS. The accurate determination of serum glucose by isotope dilution mass spectrometry—two methods. Biomed Mass Spectrom. 1982;9(9):395–405. https://doi.org/10.1002/bms.1200090907.

Cohen A, Hertz HS, Mandel J, Paule RC, Schaffer R, Sniegoski LT, u. a. Total serum cholesterol by isotope dilution/mass spectrometry: a candidate definitive method. [accessed 9 April 2026]. https://doi.org/10.1093/clinchem/26.7.854.

Welch MJ, Cohen Alex, Hertz HS, Ng KJ, Schaffer Robert, Van Der Lijn Pieter, u. a. Determination of serum creatinine by isotope dilution mass spectrometry as a candidate definitive method. Anal Chem. 1986;58(8):1681–5. https://doi.org/10.1021/ac00121a018.

Siekmann L, Breuer H. Determination of cortisol in human plasma by isotope dilution-mass spectrometry. Definitive methods in clinical chemistry, I. Bd. 20. 1982;Clinical Chemistry and Laboratory Medicine (CCLM)20(12):883–92. https://doi.org/10.1515/cclm.1982.20.12.883.

Lehmann WD. A timeline of stable isotopes and mass spectrometry in the life sciences. Mass Spectrom Rev. 2017;36(1):58–85.

Article  PubMed  CAS  Google Scholar 

CCQM: Report of the 1st meeting. 1995. https://www.bipm.org/documents/20126/40255962/1st+meeting.pdf/806db6f8-cf68-ee09-824b-4088d6df4347. Accessed 13 Mar 2026.

BIPM. Published CCQM-OAWG Key Comparisons. https://www.bipm.org/en/committees/cc/ccqm/wg/ccqm-oawg/key-comparisons. Accessed 10 Apr 2026.

Wise SA, Phinney KW, Duewer DL, Sniegoski LT, Welch MJ, Pabello G. CCQM K6.2 determination of total cholesterol in human serum. Metrologia. 2018;55(1A):08011. https://doi.org/10.1088/0026-1394/55/1A/08011.

Wise SA, Phinney KW, Duewer DL, Sniegoski LT, Welch MJ, Pritchett J. CCQM-K11.2 determination of glucose in human serum and CCQM-K12.2 determination of creatinine in human serum. Metrologia. 2018;55(1A):08012. https://doi.org/10.1088/0026-1394/55/1A/08012.

Phinney KW, Rimmer CA, Thomas JB, Sander LC, Sharpless KE, Wise SA. Isotope dilution liquid chromatography - mass spectrometry methods for fat- and water-soluble vitamins in nutritional formulations. Anal Chem. 2011;83(1):92–8. https://doi.org/10.1021/ac101950r.

Article  PubMed  CAS  Google Scholar 

Burdette CQ, Yen JH, Kuszak AJ, Wise SA. Value assignment of vitamin D and 25-hydroxyvitamin D in food-matrix standard reference materials (SRMs) using isotope dilution liquid chromatography–tandem mass spectrometry (ID LC–MS/MS). J Agric Food Chem. 2026;74(18):14607–18. https://doi.org/10.1021/acs.jafc.6c01298.

Article  PubMed  PubMed Central  CAS  Google Scholar 

Zeleny R, Rummel A, Jansson D, Dorner BG. Challenges in the development of reference materials for protein toxins. In: Merkley ED, Herausgeber. ACS Symposium Series. Washington, DC: American Chemical Society; 2019;S:185–202. https://pubs.acs.org/doi/abs/10.1021/bk-2019-1339.ch012.

Mulder GJ. Versuch einer allgemeinen physiologischen Chemie. Braunschweig: Friedrich Vieweg und Sohn; 1844.

Google Scholar 

Cinquanta L, Fontana DE, Bizzaro N. Chemiluminescent immunoassay technology: what does it change in autoantibody detection? Autoimmun Highlights. 2017;8(1):9. https://doi.org/10.1007/s13317-017-0097-2.

Article  CAS  Google Scholar 

Dong R, Yi N, Jiang D. Advances in single molecule arrays (SIMOA) for ultra-sensitive detection of biomolecules. Talanta. 2024;270:125529. https://doi.org/10.1016/j.talanta.2023.125529.

Article  PubMed  CAS  Google Scholar 

Smit NPM, Ruhaak LR, Romijn FPHTM, Pieterse MM, van der Burgt YEM, Cobbaert CM. The time has come for quantitative protein mass spectrometry tests that target unmet clinical needs. J Am Soc Mass Spectrom. 2021;32(3):636–47. https://doi.org/10.1021/jasms.0c00379.

Article  PubMed  PubMed Central  CAS  Google Scholar 

Qualitätssicherung laboratoriumsmedizinischer Untersuchungen – Rili-BÄK. Dtsch Ärztebl Online. 2023. https://doi.org/10.3238/arztebl.2023.rili_baek_QS_Labor.

Wilson S, Steele S, Adeli K. Innovative technological advancements in laboratory medicine: predicting the lab of the future. Biotechnol Biotechnol Equip. 2022;36(sup1):S9-21. https://doi.org/10.1080/13102818.2021.2011413.

Article  Google Scholar 

About. IFCC. https://ifcc.org/about/. Accessed 13 Mar 2026.

Dtsch Ärztebl Int. 1971;31:7772–31.

Directive 98/79/EC of the european parliament and of the councIL of 27 October 1998 on in vitro diagnostic medical devices (OI L 331, 7.12.1998. p. 1–37).

Regulation (EU) 2017/746 of the european parliament and of the council of 5 April 2017 on in vitro diagnostic medical devices and repealing Directive 98/79/EC and Commission Decision 2010/227/EU, OJ L 117, 5.5.2017. p. 176–332.

Reinmuth-Selzle K, Tchipilov T, Backes AT, Tscheuschner G, Tang K, Ziegler K. Determination of the protein content of complex samples by aromatic amino acid analysis, liquid chromatography-UV absorbance, and colorimetry. Anal Bioanal Chem. 2022;414(15):4457–70. https://doi.org/10.1007/s00216-022-03910-1.

Hoofnagle AN, Wener MH. The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry. J Immunol Methods. 2009;347(1):3–11. https://doi.org/10.1016/j.jim.2009.06.003.

Article  PubMed  PubMed Central  CAS  Google Scholar 

Panteghini M, Braga F. Implementation of metrological traceability in laboratory medicine: where we are and what is missing. Clin Chem Lab Med CCLM. 2020;58(8):1200–4. https://doi.org/10.1515/cclm-2019-1128.

Article  PubMed  CAS  Google Scholar 

Josephs RD, Martos G, Li M, Wu L, Melanson JE, Quaglia M. Establishment of measurement traceability for peptide and protein quantification through rigorous purity assessment—a review. Metrologia. 2019;56(4):044006. https://doi.org/10.1088/1681-7575/ab27e5.

Barber M, Bordoli RS, Sedgwick RD, Tyler AN. Fast atom bombardment of solids (F.A.B.): a new ion source for mass spectrometry. J Chem Soc Chem Commun. 1981;(7):325–7. https://doi.org/10.1039/C39810000325.

Desiderio DM, Zhu X. Quantitative analysis of methionine enkephalin and beta-endorphin in the pituitary by liquid secondary ion mass spectrometry and tandem mass spectrometry. J Chromatogr A. 1998;794(1–2):85–96. https://doi.org/10.1016/s0021-9673(97)00670-5.

Article  PubMed  CAS  Google Scholar 

Fenn JB, Mann M, Meng CK, Wong SF, Whitehouse CM. Electrospray ionization for mass spectrometry of large biomolecules. Science. 1989;246(4926):64–71. https://doi.org/10.1126/science.2675315.

Article  PubMed  CAS  Google Scholar 

Barr JR, Maggio VL, Patterson DG, Cooper GR, Henderson LO, Turner WE. Isotope dilution--mass spectrometric quantification of specific proteins: model application with apolipoprotein A-I. Clin Chem. 1996;42(10):1676–82.

Römmert AK, Ohlendorf R, Arsene C, Zhai R, Chu Z, Jin Y. CCQM-K177 - Determination of growth hormone in serum using isotope dilution mass spectrometry. Metrologia. 2025;62(1A):08026. https://doi.org/10.1088/0026-1394/62/1A/08026.

Jeong JS, Yim YH, Liu Q, Yong S, Liu H, Beltrão P. Key comparison study on protein quantification: purity-assessed recombinant protein contents in buffer solution using insulin analogue. Metrologia. 2021;58(1A):08007. https://doi.org/10.1088/0026-1394/58/1A/08007.

Prohaska T, Irrgeher J, Benefield J, Böhlke JK, Chesson LA, Coplen TB. Standard atomic weights of the elements 2021 (IUPAC Technical Report). Pure Appl Chem. 2022;94(5):573–600. https://doi.org/10.1515/pac-2019-0603.

Harrington CF, Vidler DS, Watts MJ, Hall JF. Potential for using isotopically altered metalloproteins in species-specific isotope dilution analysis of proteins by HPLC coupled to inductively coupled plasma mass spectrometry. Anal Chem. 2005;77(13):4034–41. https://doi.org/10.1021/ac050256t.

Article  PubMed  CAS  Google Scholar 

De Bièvre P, Peiser HS. Basic equations and uncertainties in isotope-dilution mass spectrometry for traceability to SI of values obtained by this primary method. Fresenius J Anal Chem. 1997;359(7):523–5. https://doi.org/10.1007/s002160050625.

Article  Google Scholar 

Laeter JR de, Böhlke JK, Bièvre PD, Hidaka H, Peiser HS, Rosman KJR. Atomic weights of the elements. Review 2000 (IUPAC Technical Report). Pure Appl Chem. 2003;75(6):683–800. https://doi.org/10.1351/pac200375060683.

Pramann A, Rienitz O. Blank correction in IDMS: possible pitfalls. J Anal At Spectrom. 2026;41(6):2127–36. https://doi.org/10.1039/D6JA00070C.

Article  CAS  Google Scholar 

Vogl J. Measurement uncertainty in single, double and triple isotope dilution mass spectrometry. Rapid Commun Mass Spectrom. 2012;26(3):275–81. https://doi.org/10.1002/rcm.5306.

Article  PubMed  CAS  Google Scholar 

Lee HS, Kim SH, Jeong JS, Lee YM, Yim YH. Sulfur-based absolute quantification of proteins using isotope dilution inductively coupled plasma mass spectrometry. Metrologia. 2015;52(5):619. https://doi.org/10.1088/0026-1394/52/5/619.

Article  CAS  Google Scholar 

Rappel C, Schaumlöffel D. The role of sulfur and sulfur isotope dilution analysis in quantitative protein analysis. Anal Bioanal Chem. 2008;390(2):605–15. https://doi.org/10.1007/s00216-007-1607-2.

Article  PubMed  CAS  Google Scholar 

Busto ME del C, Oster C, Cuello-Nuñez S, Deitrich CL, Raab A, Konopka A. Accurate quantification of selenoproteins in human plasma/serum by isotope dilution ICP-MS: focus on selenoprotein P. J Anal At Spectrom. 2016;31(9):1904–12. https://doi.org/10.1039/C6JA00122J.

Coverdale JamesPC, Harrington CF, Solovyev N. Review: Advances in the accuracy and traceability of metalloprotein measurements using isotope dilution inductively coupled plasma mass spectrometry. Crit Rev Anal Chem. 2024;54(7):2259–76. https://doi.org/10.1080/10408347.2022.2162811.

Bettmer J, Montes Bayón M, Ruiz Encinar J, Fernández Sánchez ML, Fernández de la Campa M, Sanz Medel A. The emerging role of ICP-MS in proteomic analysis. J Proteomics. 2009;72(6):989–1005.

Article  PubMed  CAS  Google Scholar 

Burkitt WI, Pritchard C, Arsene C, Henrion A, Bunk D, O’Connor G. Toward Système International d’Unité-traceable protein quantification: from amino acids to proteins. Anal Biochem. 2008;376(2):242–51.

Article  PubMed 

Comments (0)

No login
gif