von Graefe A. Beiträge zur pathologie und therapie des glaucoms. Arch Ophthalmol. 1869;15:108–252 (in German).
Chandler PA, Simmons RJ, Grant WM. Malignant glaucoma: medical and surgical treatment. Am J Ophthalmol. 1968;66:495–502.
Article CAS PubMed Google Scholar
Krix-Jachym K, Żarnowski T, Rękas M. Risk factors of malignant glaucoma occurrence after glaucoma surgery. J Ophthalmol. 2017;2017:9616738.
Article PubMed PubMed Central Google Scholar
Wang M, Tan Q, Jiang H, Xia X, Wang P, Jiang J, et al. Clinical analysis of malignant glaucoma after glaucoma surgery. Zhong Nan Da Xue Xue Bao Yi Xue Ban. 2015;40:543–8 (in Chinese).
Dave P, Senthil S, Rao HL, Garudadri CS. Treatment outcomes in malignant glaucoma. Ophthalmology. 2013;120:984–90.
Debrouwere V, Stalmans P, Van Calster J, Spileers W, Zeyen T, Stalmans I. Outcomes of different management options for malignant glaucoma: a retrospective study. Graefes Arch Clin Exp Ophthalmol. 2012;250:131–41.
Little BC, Hitchings RA. Pseudophakic malignant glaucoma: Nd:YAG capsulotomy as a primary treatment. Eye (Lond). 1993;7(Pt 1):102–4.
Chandler PA. Malignant glaucoma. Trans Am Ophthalmol Soc. 1950;48:128–43.
CAS PubMed PubMed Central Google Scholar
Honjo M, Sakata R, Fujishiro T, Shirato S, Aihara M. One-year postoperative outcomes of filtration minimally invasive glaucoma surgery using the Preserflo® Microshunt for primary open angle glaucoma in japanese patients. Nippon Ganka Gakkai Zasshi. 2020;124:705–12 (in Japanese).
Batlle JF, Corona A, Albuquerque R. Long-term results of the Preserflo Microshunt in patients with primary open-angle glaucoma from a single-center nonrandomized study. J Glaucoma. 2021;30:281–6.
Beckers HJM, Aptel F, Webers CAB, Bluwol E, Martínez-de-la-Casa JM, García-Feijoó J, et al. Safety and effectiveness of the Preserflo® Microshunt in primary open-angle glaucoma: results from a 2-year multicenter study. Ophthalmol Glaucoma. 2022;5:195–209.
Gambini G, Carlà MM, Giannuzzi F, Caporossi T, De Vico U, Savastano A, et al. PreserFlo(®) MicroShunt: an overview of this minimally invasive device for open-angle glaucoma. Vision (Basel). 2022;6:12.
Ahmed IIK, Sadruddin O, Panarelli JF. Subconjunctival filtration in evolution: current evidence on MicroShunt implantation for treating patients with glaucoma. Eye Vis (Lond). 2023;10:10.
Armstrong JJ, De Francesco T, Ma J, Schlenker MB, Ahmed IIK. Ab externo SIBS microshunt with mitomycin C for open-angle glaucoma: three-year results as a primary surgical intervention. Ophthalmol Glaucoma. 2023;6:480–92.
Panarelli JF, Moster MR, Garcia-Feijoo J, Flowers BE, Baker ND, Barnebey HS, et al. Ab-externo MicroShunt versus trabeculectomy in primary open-angle glaucoma: two-year results from a randomized, multicenter study. Ophthalmology. 2024;131:266–76.
Gizzi C, Costa G, Servadei R, Abed E, Ning B, Sharma A, et al. A case of malignant glaucoma following insertion of Preserflo™ MicroShunt. Eur J Ophthalmol. 2022;32:Np115–9.
Malick H, Wilde C, Stead RE. Combined aqueous misdirection and persistent choroidal effusions following implantation of a Preserflo MicroShunt. Int J Ophthalmol. 2023;16:652–5.
Article PubMed PubMed Central Google Scholar
Foreman-Larkin J, Netland PA, Salim S. Clinical management of malignant glaucoma. J Ophthalmol. 2015;2015:283707.
Article PubMed PubMed Central Google Scholar
Heindl LM, Koch KR, Cursiefen C, Konen W. Optical coherence tomography and ultrasound biomicroscopy in the management of pseudophakic malignant glaucoma. Graefes Arch Clin Exp Ophthalmol. 2013;251:2261–3.
Burgansky-Eliash Z, Ishikawa H, Schuman JS. Hypotonous malignant glaucoma: aqueous misdirection with low intraocular pressure. Ophthalmic Surg Lasers Imaging. 2008;39:155–9.
Kumar S, Singla E, Ichhpujani P, Rehman O. Hypotonous malignant glaucoma following glaucoma drainage device implantation. Indian J Ophthalmol. 2021;1:512–4.
Mieno H, Mori K, Yoshii K, Okada Y, Ikeda Y, Ueno M, et al. Risk factors and protective strategies for hypotony following preserflo microshunt implantation. Sci Rep. 2025;15:8344.
Article CAS PubMed PubMed Central Google Scholar
Lin H, Li J, Zheng X, Wan R, Zhou M, Ding Y, et al. Incidence and characteristics of aqueous misdirection after glaucoma surgery in Chinese patients with primary angle-closure glaucoma. Eye Vis. 2023;10:28.
Sadeghi R, Momeni A, Fakhraie G, Eslami Y, Zarei R, Vahedian Z, et al. Management of malignant glaucoma. J Curr Ophthalmol. 2022;34:389–97.
Wilde C, Morales MU, Kumudhan D, Sim J, Amoaku W. Spontaneous onset pseudophakic malignant glaucoma secondary to zonular weakness and cilio-lenticular block. Oman J Ophthalmol. 2018;11:178–80.
Article PubMed PubMed Central Google Scholar
Grzybowski A, Kanclerz P. Acute and chronic fluid misdirection syndrome: pathophysiology and treatment. Graefes Arch Clin Exp Ophthalmol. 2018;256:135–54.
Madgula IM, Anand N. Long-term follow-up of zonulo-hyaloido-vitrectomy for pseudophakic malignant glaucoma. Indian J Ophthalmol. 2014;62:1115–20.
Article PubMed PubMed Central Google Scholar
Rękas M, Krix-Jachym K, Żarnowski T. Evaluation of the effectiveness of surgical treatment of malignant glaucoma in pseudophakic eyes through partial PPV with establishment of communication between the anterior chamber and the vitreous cavity. J Ophthalmol. 2015;2015:873124.
Comments (0)